99 research outputs found

    Whole organic electronic synapses for dopamine detection

    Get PDF
    A whole organic artificial synapse has been fabricated by patterning PEDOT:PSS electrodes on PDMS that are biased in frequency to yield a STP response. The timescale of the STP response is shown to be sensitive to the concentration of dopamine, DA, a neurotransmitter relevant for monitoring the development of Parkinson's disease and potential locoregional therapies. The sensitivity of the sensor towards DA has been validated comparing signal variation in the presence of DA and its principal interfering agent, ascorbic acid, AA. The whole organic synapse is biocompatible, soft and flexible, and is attractive for implantable devices aimed to real-time monitoring of DA concentration in bodily fluids. This may open applications in chronic neurodegenerative diseases such as Parkinson's disease

    The Substrate is a pH-Controlled Second Gate of Electrolyte-Gated Organic Field-Effect Transistor

    Get PDF
    Electrolyte-gated organic field-effect transistors (EGOFETs), based on ultra-thin pentacene films on quartz, were operated with electrolyte solutions whose pH was systematically changed. Transistor parameters exhibit non-monotonic variation vs pH, which cannot be accounted for by capacitive coupling through the Debye-Helmholtz layer. The data were fitted with an analytical model of the accumulated charge in the EGOFET where Langmuir adsorption was introduced to describe the (pH-dependent) charge build-up at the quartz surface. The model provides an excellent fit to the threshold voltage and transfer characteristics as a function of pH, which demonstrates that quartz acts as a second gate controlled by pH, and is mostly effective at neutral or alkaline pH. The effective capacitance of the device is always greater than the capacitance of the electrolyte, thus highlighting the role of the substrate as an important active element for amplification of the transistor response

    A comprehensive suite of earthquake catalogues for the 2016-2017 Central Italy seismic sequence

    Get PDF
    The protracted nature of the 2016-2017 central Italy seismic sequence, with multiple damaging earthquakes spaced over months, presented serious challenges for the duty seismologists and emergency managers as they assimilated the growing sequence to advise the local population. Uncertainty concerning where and when it was safe to occupy vulnerable structures highlighted the need for timely delivery of scientifically based understanding of the evolving hazard and risk. Seismic hazard assessment during complex sequences depends critically on up-to-date earthquake catalogues—i.e., data on locations, magnitudes, and activity of earthquakes—to characterize the ongoing seismicity and fuel earthquake forecasting models. Here we document six earthquake catalogues of this sequence that were developed using a variety of methods. The catalogues possess different levels of resolution and completeness resulting from progressive enhancements in the data availability, detection sensitivity, and hypocentral location accuracy. The catalogues range from real-time to advanced machine-learning procedures and highlight both the promises as well as the challenges of implementing advanced workflows in an operational environment

    Segmental transverse colectomy. Minimally invasive versus open approach: results from a multicenter collaborative study

    Get PDF
    none65noThe role of minimally invasive surgery in the treatment of transverse colon cancer is still controversial. The aim of this study is to investigate the advantages of a totally laparoscopic technique comparing open versus laparoscopic/robotic approach. Three hundred and eighty-eight patients with transverse colon cancer, treated with a segmental colon resection, were retrospectively analyzed. Demographic data, tumor stage, operative time, intraoperative complications, number of harvested lymph nodes and recovery outcomes were recorded. Recurrences and death were also evaluated during the follow-up. No differences were found between conventional and minimally invasive surgery, both for oncological long-term outcomes (recurrence rate p = 0.28; mortality p = 0.62) and postoperative complications (overall rate p = 0.43; anemia p = 0.78; nausea p = 0.68; infections p = 0.91; bleeding p = 0.62; anastomotic leak p = 0.55; ileus p = 0.75). Nevertheless, recovery outcomes showed statistically significant differences in favor of minimally invasive surgery in terms of time to first flatus (p = 0.001), tolerance to solid diet (p = 0.017), time to first mobilization (p = 0.001) and hospital stay (p = 0.004). Compared with laparoscopic approach, robotic surgery showed significantly better results for time to first flatus (p = 0.001), to first mobilization (p = 0.005) and tolerance to solid diet (p = 0.001). Finally, anastomosis evaluation confirmed the superiority of intracorporeal approach which showed significantly better results for time to first flatus (p = 0.001), to first mobilization (p = 0.003) and tolerance to solid diet (p = 0.001); moreover, we recorded a statistical difference in favor of intracorporeal approach for infection rate (p = 0.04), bleeding (p = 0.001) and anastomotic leak (p = 0.03). Minimally invasive approach is safe and effective as the conventional open surgery, with comparable oncological results but not negligible advantages in terms of recovery outcomes. Moreover, we demonstrated that robotic approach may be considered a valid option and an intracorporeal anastomosis should always be preferred.noneMilone, Marco; Degiuli, Maurizio; Velotti, Nunzio; Manigrasso, Michele; Vertaldi, Sara; D'Ugo, Domenico; De Palma, Giovanni Domenico; Dario Bruzzese, Giuseppe Servillo, Giuseppe De Simone, Katia Di Lauro, Silvia Sofia, Marco Ettore Allaix, Mario Morino, Rossella Reddavid, Carlo Alberto Ammirati, Stefano Scabini, Gabriele Anania, Cristina Bombardini, Andrea Barberis, Roberta Longhin, Andrea Belli, Francesco Bianco, Giampaolo Formisano, Giuseppe Giuliani, Paolo Pietro Bianchi, Davide Cavaliere, Leonardo Solaini, Claudio Coco, Gianluca Rizzo, Andrea Coratti, Raffaele De Luca, Michele Simone, Alberto Di Leo, Giovanni De Manzoni, Paola De Nardi, Ugo Elmore, Riccardo Rosati, Andrea Vignali, Paolo Delrio, Ugo Pace, Daniela Rega, Antonio Di Cataldo, Giovanni Li Destri, Annibale Donini, Luigina Graziosi, Andrea Fontana, Michela Mineccia, Sergio Gentilli, Manuela Monni, Mario Guerrieri, Monica Ortenzi, Francesca Pecchini, Micaela Piccoli, Italy. Corrado Pedrazzani, Giulia Turri, Sara Pollesel, Franco Roviello, Marco Rigamonti, Michele Zuolo, Mauro Santarelli, Federica Saraceno, Pierpaolo Sileri Giuseppe Sigismondo Sica, Luigi Siragusa Salvatore Pucciarelli, Matteo ZuinMilone, Marco; Degiuli, Maurizio; Velotti, Nunzio; Manigrasso, Michele; Vertaldi, Sara; D'Ugo, Domenico; De Palma, Giovanni Domenico; Dario Bruzzese, Giuseppe Servillo, Giuseppe De Simone, Katia Di Lauro, Silvia Sofia, Marco Ettore Allaix, Mario Morino, Rossella Reddavid, Carlo Alberto Ammirati, Stefano Scabini, Gabriele Anania, Cristina Bombardini, Andrea Barberis, Roberta Longhin, Andrea Belli, Francesco Bianco, Giampaolo Formisano, Giuseppe Giuliani, Paolo Pietro Bianchi, Davide Cavaliere, Leonardo Solaini, Claudio Coco, Gianluca Rizzo, Andrea Coratti, Raffaele De Luca, Michele Simone, Alberto Di Leo, Giovanni De Manzoni, Paola De Nardi, Ugo Elmore, Riccardo Rosati, Andrea Vignali, Paolo Delrio, Ugo Pace, Daniela Rega, Antonio Di Cataldo, Giovanni Li Destri, Annibale Donini, Luigina Graziosi, Andrea Fontana, Michela Mineccia, Sergio Gentilli, Manuela Monni, Mario Guerrieri, Monica Ortenzi, Francesca Pecchini, Micaela Piccoli, Italy. Corrado Pedrazzani, Giulia Turri, Sara Pollesel, Franco Roviello, Marco Rigamonti, Michele Zuolo, Mauro Santarelli, Federica Saraceno, Pierpaolo Sileri Giuseppe Sigismondo Sica, Luigi Siragusa Salvatore Pucciarelli, Matteo Zui

    Quality control of B-lines analysis in stress Echo 2020

    Get PDF
    Background The effectiveness trial “Stress echo (SE) 2020” evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. Purpose To provide web-based upstream quality control and harmonization of B-lines reading criteria. Methods 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module ( http://se2020.altervista.org ). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. Results All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p < .01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p < .01). Conclusions Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly.info:eu-repo/semantics/publishedVersio

    Fine‐Scale Structure of the 2016–2017 Central Italy Seismic Sequence From Data Recorded at the Italian National Network

    No full text
    We explore the three‐dimensional structure of the 2016–2017 Central Italy sequence using ~34,000 ML ≥ 1.5 earthquakes that occurred between August 2016 and January 2018. We applied cross‐correlation and double‐difference location methods to waveform and parametric data routinely produced at the Italian National Institute of Geophysics and Volcanology. The sequence activated an 80 km long system of normal faults and near‐horizontal detachment faults through the MW 6.0 Amatrice, the MW 5.9 Visso, and the MW 6.5 Norcia mainshocks and aftershocks. The system has an average strike of N155°E and dips 38°–55° southwestward and is segmented into 15–30 km long faults individually activated by the cascade of MW ≥ 5.0 shocks. The two main normal fault segments, Mt. Vettore‐Mt. Bove to the North and Mt. della Laga to the South, are separated by an NNE‐SSW‐trending lateral ramp of the Sibillini thrust, a regional structure inherited from the previous compressional tectonic phase putting into contact diverse lithologies with different seismicity patterns. Space‐time reconstruction of the fault system supports a composite rupture scenario previously proposed for the MW 6.5 Norcia earthquake, where the rupture possibly propagated also along an oblique portion of the Sibillini thrust. This dissected set of normal fault segments is bounded at 8–10 km depth by a continuous 2 km thick seismicity layer of extensional nature slightly dipping eastward and interpreted as a shear zone. All three mainshocks in the sequence nucleated along the high‐angle planes at significant distance from the shear zone, thus complicating the interpretation of the mechanisms driving strain partitioning between these structures.Publishede2019JB0184403T. Sorgente sismicaJCR Journa

    Elettronica organica

    No full text
    Lemma "Elettronica Organica" definisce il settore tecnologico e scientifico, ne descrive i fondamenti e le applicazioni sul mercato e in via di sviluppo
    corecore